+86-134-8004-8861
TU 2000W
Category:
DESCRIPTION
|
Category |
TU600VA TUP600VA |
TU1000VA TUP1000VA |
TU1200VA TUP1200VA |
TU2000VA TUP2000VA |
TU2400VA TUP2400VA |
TU3000VA TUP3000VA |
||
|
Inverter parameters |
||||||||
|
Apparent Power |
600VA |
1000VA |
1200VA |
2000VA |
2400VA |
3000VA |
||
|
Rated Power |
480W |
800W |
960W |
1600W |
1920W |
2400W |
||
|
Peak power |
960W |
1600W |
1920W |
3200W |
3940W |
4800W |
||
|
Output waveform |
Modified sine wave |
|||||||
|
Input voltage |
12VDC Mode: 10VDC–15VDC (12VDC supply at 100%) 24VDC Mode: 20VDC–30VDC (100% power supply at 24VDC) 12V/24VDC Dual Voltage Mode: 10VDC–30VDC (80% at 12VDC supply, 100% at 24VDC supply) |
|||||||
|
Output voltage |
110V series: 100Vac–120Vac, 230V series: 207Vac–253Vac |
|||||||
|
Output frequency |
50 Hz / 60 Hz ± 0.3 Hz |
|||||||
|
Conversion efficiency |
12V Mode: ≥86% 24V Mode: ≥90% |
|||||||
|
Mains Bypass Parameters |
||||||||
|
Mains input voltage |
220/230/240Vac 170–280 VAC (single voltage for AC charging) 90–280 VAC (Full Voltage in Bypass Mode) |
|||||||
|
Municipal power frequency |
50Hz |
|||||||
|
Output AC voltage |
Identical to the input |
|||||||
|
Output frequency of the AC |
Identical to the input |
|||||||
|
Battery pack specifications |
12V |
24V |
||||||
|
Maximum Charging Current from Mains Power |
15A |
10-12A |
||||||
|
Float charging voltage |
13.75 ± 0.2 V |
27.5 ± 0.4 V |
||||||
|
Overcharge voltage |
15.0 ± 0.4 V |
30.0 ± 0.8 V |
||||||
|
Municipal Electricity Efficiency |
>97% |
|||||||
|
Switching time |
<20ms |
|||||||
|
Solar charging parameters |
||||||||
|
Battery pack specifications |
12V |
24V |
||||||
|
Solar panel input range |
18Vdc to 30Vdc |
33Vdc to 60Vdc |
||||||
|
Maximum charging current |
30A |
|||||||
|
Applicable Models |
TUP600VA/TUP1000VA/TUP1200VA/TUP2000VA/TUP2400VA/TUP3000VA |
|||||||
|
Other parameters |
||||||||
|
Human-Computer Interaction |
Solar charging, mains charging, inversion, battery voltage, output power |
|||||||
|
Protection feature |
Undervoltage protection, overvoltage protection, overheating protection, overload protection, short-circuit protection, overcharge protection, and over-discharge protection |
|||||||
|
Fault code |
E01--Communication Failure E02—Inverter Short-Circuit Protection E03 – Inverter Overload Protection E04--Overtemperature Protection E05—PV Overcurrent Protection E06 – Overvoltage Protection for Batteries E07 – Battery Undervoltage Protection E08 – Other Inverter Alarms E09 – Battery Short Circuit |
|||||||
|
Reverse Polarity Protection |
FUSE |
|||||||
|
Cooling method |
Cooling Fan Temperature Control |
|||||||
|
Work environment |
-20°C to 45°C |
|||||||
Keyword:
Message
Professional Service Team Answers