+86-134-8004-8861
TU 1000W
Category:
DESCRIPTION
|
Category |
TU600VA TUP600VA |
TU1000VA TUP1000VA |
TU1200VA TUP1200VA |
TU2000VA TUP2000VA |
TU2400VA TUP2400VA |
TU3000VA TUP3000VA |
||
|
Inverter Parameters |
||||||||
|
Apparent Power |
600VA |
1000VA |
1200VA |
2000VA |
2400VA |
3000VA |
||
|
Rated Power |
480W |
800W |
960W |
1600W |
1920W |
2400W |
||
|
Peak Power |
960W |
1600W |
1920W |
3200W |
3940W |
4800W |
||
|
Output Waveform |
Modified Sine Wave |
|||||||
|
Input Voltage |
12VDC Mode: 10VDC~15VDC (12VDC power supply 100%) 24VDC Mode: 20VDC~30VDC (24VDC power supply 100%) 12V/24VDC Dual Voltage Mode: 10VDC~30VDC (12VDC power supply 80%, 24VDC power supply 100%) |
|||||||
|
Output Voltage |
110V series: 100Vac~120Vac, 230V series: 207Vac~253Vac |
|||||||
|
Output Frequency |
50HZ/60HZ ± 0.3HZ |
|||||||
|
Conversion Efficiency |
12V Mode: ≥86% 24V Mode: ≥90% |
|||||||
|
Mains Bypass Parameters |
||||||||
|
Mains Input Voltage |
220/230/240Vac 170~280Vac (AC charging single voltage)/ 90~280Vac (Bypass full voltage operation) |
|||||||
|
Mains Frequency |
50Hz |
|||||||
|
AC Output Voltage |
Same as input |
|||||||
|
AC Output Frequency |
Same as input |
|||||||
|
Battery Pack Specifications |
12V |
24V |
||||||
|
Maximum Mains Charging Current |
15A |
10-12A |
||||||
|
Float Charging Voltage |
13.75±0.2V |
27.5±0.4V |
||||||
|
Overcharge Voltage |
15.0±0.4V |
30.0±0.8V |
||||||
|
Mains Efficiency |
>97% |
|||||||
|
Switching Time |
<20ms |
|||||||
|
Solar Charging Parameters |
||||||||
|
Battery Pack Specifications |
12V |
24V |
||||||
|
Solar Panel Input Range |
18Vdc~30 Vdc |
33Vdc~60Vdc |
||||||
|
Maximum Charging Current |
30A |
|||||||
|
Applicable Models |
TUP600VA/TUP1000VA/TUP1200VA/TUP2000VA/TUP2400VA/TUP3000VA |
|||||||
|
Other Parameters |
||||||||
|
Human-Machine Interaction |
Solar charging, mains charging, inversion, battery voltage, output power |
|||||||
|
Protection Functions |
Under-voltage protection, over-voltage protection, overheat protection, overload protection, short circuit protection, overcharge protection, over-discharge protection |
|||||||
|
Fault Codes |
E01--Communication Failure E02--Inverter Short Circuit Protection E03--Inverter Overload Protection E04--Over Temperature Protection E05--PV Overcurrent Protection E06--Battery Overvoltage Protection E07--Battery Undervoltage Protection E08--Other Inverter Alarms E09--Battery Short Circuit |
|||||||
|
Reverse Polarity Protection |
FUSE |
|||||||
|
Cooling Method |
Cooling Fan Temperature Control |
|||||||
|
Operating Environment |
-20℃~45℃ |
|||||||
Keyword:
Message