  • jimeng-2025-11-17-2210-将产品上的“3000VA”文字改为“2000VA”.png
  • TU 2000W.jpg
  • 21 (1).png
  • 21 (2).png

TU 2000W

Input Voltage 12 VDC mode: 10 VDC to 15 VDC (100% powered by 12 VDC) 24 VDC mode: 20 VDC to 30 VDC (100% powered by 24 VDC) 12 V/24 VDC dual-voltage mode: 10 VDC to 30 VDC (80% powered by 12 VDC, 100% powered by 24 VDC)

Category:


Product Description

Category

TU600VA

TUP600VA

TU1000VA

TUP1000VA

TU1200VA

TUP1200VA

TU2000VA

TUP2000VA

TU2400VA

TUP2400VA

TU3000VA

TUP3000VA

Inverter parameters

Apparent power

600VA

1000VA

1200VA

2000VA

2400VA

3000VA

Rated power

480W

800W

960W

1600W

1920W

2400W

Peak power

960W

1600W

1920W

3200W

3940W

4800W

Output waveform

Modified Sine Wave

Input voltage

12 VDC mode: 10 VDC to 15 VDC (12 VDC supply at 100%)
24 VDC mode: 20 VDC to 30 VDC (100% powered by 24 VDC)
12V/24VDC dual-voltage mode: 10VDC–30VDC (80% at 12VDC supply, 100% at 24VDC supply)

Output voltage

110V series: 100Vac–120Vac, 230V series: 207Vac–253Vac

Output frequency

50 Hz/60 Hz ± 0.3 Hz

Conversion efficiency

12V Mode: ≥86% 24V Mode: ≥90%

Mains Bypass Parameters

Mains input voltage

220/230/240Vac

170~280 Vac (single-voltage AC charging)/

90~280 Vac (full voltage in bypass mode)

Mains frequency

50Hz

AC output voltage

Same as the input

AC output frequency

Same as the input

Battery Pack Specifications

12V

24V

Maximum charging current from the mains

15A

10-12A

Float charging voltage

13.75±0.2V

27.5±0.4V

Overcharge voltage

15.0±0.4V

30.0±0.8V

Mains efficiency

>97%

Switching Time

<20ms

Solar Charging Parameters

Battery Pack Specifications

12V

24V

Solar panel input range

18 Vdc ~ 30 Vdc

33 Vdc ~ 60 Vdc

Maximum charging current

30A

Applicable Models

TUP600VA/TUP1000VA/TUP1200VA/TUP2000VA/TUP2400VA/TUP3000VA

Other parameters

Human-Computer Interaction

Solar charging, mains charging, inversion, battery voltage, output power

Protection Function

Undervoltage protection, overvoltage protection, overheating protection, overload protection, short-circuit protection, overcharge protection, and overdischarge protection.

Fault code

E01--Communication Failure

E02--Inverter Short-Circuit Protection

E03--Inverter Overload Protection

E04--Overtemperature Protection

E05--PV Overcurrent Protection

E06--Battery Overvoltage Protection

E07—Battery Undervoltage Protection

E08—Other Inverter Alarms

E09--Battery Short Circuit

Reverse Polarity Protection

FUSE

Cooling method

Cooling Fan Temperature Control

Work environment

-20℃~45℃

Keywords:

Leave a Message

Professional service team response