  • 9 (5).jpg
  • TeslaPlus1000W-1.jpg
  • TeslaPlus1000W-2.jpg
  • TeslaPlus1000W-3.jpg
  • TeslaPlus1000W-4.jpg
  • TeslaPlus1000W-5.jpg
  • 插头1000.jpg

TESLA-PLUS 1000W

1. Conversion efficiency of 95% or higher 2. Waveform and stability identical to those of the utility grid, with no damage to the load 3. Excellent immunity to electromagnetic and radio-frequency interference 4. Intelligent temperature-controlled fan for low noise operation 5. Comprehensive protection features: overvoltage, undervoltage, overload, overheating, and short-circuit protection 6. Automatic recovery function 7. CE, ETL, or other certifications as required by the customer can be provided 8. Optional plug configurations for various countries 9. LCD display showing fault codes that indicate the cause of any illuminated red indicator light 10. Robust metal enclosure with a premium tactile finish 11. Built-in heat dissipation system 12. Optional single-voltage input of DC 12V or 24V; dual-voltage input of DC 12V and 24V is also available 13. After-sales service will be provided in accordance with the terms specified in the purchase order.


Product Description

TES-PLUS 1000W Dual-Voltage Input Pure Sine Wave Inverter with Display – Specification Sheet

  Power 1000W
Input parameters Rated Input Voltage 12V DC / 24V DC
Rated Input Voltage Range 10.2~15.2V DC / 22~29V DC
Undervoltage protection threshold 9~10.2V DC / 19.4~21.5V DC
Overvoltage protection threshold 15.2~16V DC / 29.5~31.5V DC
Output parameters Rated output power 1000W
Rated Output Voltage 230V AC
Rated Output Frequency 50 Hz ± 0.1 Hz
Peak Output Power 2000W
Overload protection point 105%~115% load
Output waveform Pure sine wave output
Permitted ambient temperature -20 ~ +40 ℃
Permitted relative humidity 0–90%, no condensation
Protection Function Short circuit, overvoltage, undervoltage, overheating, and overload
Conversion efficiency (100% resistive load) 90~95%
Display Display mode LCD
Display Content 1. DC voltage 2. AC voltage 3. Frequency 4. Battery format 5. Fault code
Fault code display content

1. PV overvoltage 2. Busbar overvoltage 3. Busbar undervoltage 4. Inverter overload

5. Inverter overheat 6. Inverter overload (minor) 7. Inverter output undervoltage 8. Battery undervoltage

9. The fuse has blown. 10. Inverter short circuit. 11. Battery overvoltage.

Other Functional Requirements USB port None
Inverter with automatic recovery function Overvoltage, undervoltage, overtemperature
Cooling method Temperature-controlled fan

 

Product Packaging Specification
Product Model SDY-SIP1000W
Host weight 1. 575 kG
Net weight/Gross weight 19.5/20.5KG
Host dimensions
(Total length including terminal posts)
320*105*88mm
Set/Box 10 set
Outer box dimensions 320*505*390mm

Keywords:

Leave a Message

Professional service team response