HT-A 600W Dual-Voltage Input

12 VDC mode: 10 VDC to 15 VDC (100% powered by 12 VDC) 24 VDC mode: 20 VDC to 30 VDC (100% powered by 24 VDC) 12 V/24 VDC dual-voltage mode: 10 VDC to 30 VDC (80% powered by 12 VDC, 100% powered by 24 VDC)

Category:


Product Description

Category

HT150/210A/B/C/D

HT300/420A/B/C/D

HT600/840A/B/C/D

HT1300/1800A/B/C/D

HT1500/2000A/B/C/D

HT2000/3000A/B/C/D

HT3000/5000A/B/C/D

Rated power

12V100W

24V210W

12V300W

24V420W

12V600W

24V840W

12V1000W

24V1500W

12V1500W

24V2000W

12V2000W

24V3000W

12V3000W

24V5000W

Constant-power operation

24V ≥ 210W

24V ≥ 420W

24V≥840W

24V ≥ 1500W

24V ≥ 2000W

24V ≥ 3000W

24V ≥ 5000W

Peak power

12V300W

24V420W

12V600W

24V840W

12V1200W

24V1600W

12V2000W

24V3000W

12V3000W

24V4000W

12V4000W

24V6000W

12V6000W

24V10000W

Output waveform

Modified Sine Wave

Input voltage

12 VDC mode: 10 VDC to 15 VDC (100% powered by 12 VDC)
24 VDC mode: 20 VDC to 30 VDC (100% powered by 24 VDC)
12V/24VDC dual-voltage mode: 10VDC–30VDC (80% at 12VDC supply, 100% at 24VDC supply)

Output voltage

110V series: 110Vac~120Vac, 220V series: 220Vac~240Vac

Output frequency

50 Hz/60 Hz ± 0.3 Hz

Conversion efficiency

12V Mode: ≥86% 24V Mode: ≥90%

Protection function

Undervoltage protection, overvoltage protection, overheating protection, overload protection, short-circuit protection

Fault code

E01-- Short-circuit protection

E02-- Overload Protection

E03--Overtemperature Protection

E04--Undervoltage Protection

E05--Overvoltage Protection

Reverse Polarity Protection

FUSE

Cooling method

Cooling Fan Temperature Control

Work environment

-10℃~50℃

 

Category

USB A

TYPE C

LED display

LED indicator light

 

Supports QC fast charging

5V3A

9V2A

12V1.5A

Supports PD fast charging

5V3A

9V3A

12V2.25A

Display content:

Input voltage, battery level, output voltage, output frequency, output load percentage, fault code, and operating status icon.

The green light is functioning normally.

The red light is malfunctioning.