Oudeson Power Co.,Ltd
HT-B 3000W Dual-Voltage Input
Category:
Product Description
| Input parameters |
||
| Rated Input Voltage |
12VDC |
24VDC |
| Rated Input Voltage Range |
10 VDC ~ 15 VDC |
20 VDC–30 VDC |
| Undervoltage protection threshold |
9.7V~10V DC |
19.5V-20VDC |
| Overvoltage protection threshold |
15.2V~15.8V DC |
29.8V-30.5VDC |
| Output parameters |
||
| Rated Output Power |
12V1300W |
24V1800W |
| Rated Output Voltage |
230V AC |
|
| Rated Output Frequency |
50 Hz ± 3 Hz |
|
| Peak Output Power |
12V2600W |
24V3600W |
| Overload protection point |
105%~115% load |
|
| Output waveform |
Modified Sine Wave Output |
|
| Permitted ambient temperature |
-20 ~ +40℃ |
|
| Permitted relative humidity |
0–90%, no condensation |
|
| Protection Function |
Short circuit, overvoltage, undervoltage, overheating, and overload |
|
| Conversion efficiency (100% resistive load) |
84%~89% |
|
| Other Functional Requirements |
||
| USB port |
QC 5V, 9V, 12V, 3.0A, PD 30W |
|
| Inverter with automatic recovery function |
Yes |
|
| Cooling method |
Temperature-controlled fan |
|
Keywords:
Previous
Next
Leave a Message
Professional service team response