Oudeson Power Co.,Ltd
Product Description
I. Panel and Interfaces


- XT90 : Battery input terminal
- Switch : Press to ON Turn on the power at the location, press to OFF Turn off the power at the location.
- LED Indicator light: displays the power supply operating status
- XT60:12V Voltage Output Terminal
- Fan: Turn on the fan when the product is operating.
- DC5525 : Adapter or solar panel input, for charging the battery
II. Operating Instructions
2.1 Battery Discharge Instructions
- Before connecting the battery, please use our company’s dedicated connection cable to link the product. Prior to powering on, carefully verify that the battery meets the product’s specifications.
- Press the power switch to ON Position: At this point, the product’s status indicator light is green, indicating that the output is normal, and the device can now be connected and used. Press to OFF Then, disable the product;
- If the device will not be used for an extended period, please disconnect the power cable to help preserve and extend the battery life.
2.2 Current Charging Instructions
- When the battery is low, it can be charged using an adapter or a solar panel; select the appropriate voltage for the adapter or solar panel. 5-25VDC the parameters;
- The charging port input is DC5525 Connector: positive inside, negative outside. Please verify the voltage and polarity before inserting, and simultaneously switch the power supply to ON Location;
- Once the device is fully charged, it will automatically stop charging. At this point, please disconnect the charger or the solar panel input cable.
III. Parameter Table
| battery Parameters |
|
| Rated Input Voltage |
3.2VDC |
| Rated Input Voltage Range |
2.5 VDC~ 3.65 VDC |
| Undervoltage protection threshold |
2.3 VDC~ 2.6 VDC |
| Undervoltage recovery value |
2.8VDC-3.2VDC |
| Input connector |
XT90 |
| DC Output parameters |
|
| Rated Output Power |
120W |
| Rated Output Voltage |
12VDC |
| Output voltage range |
11.4VDC-12.6VDC |
| Overload protection |
Constant-power operation |
| Charging Input parameters |
|
| Rated Input Voltage |
12VDC |
| Rated input power Flow |
greater than or equal to 10A |
| Rated Input Voltage Range |
10 VDC~ 25 VDC |
| MPPT function |
Yes, this item is optional. |
| Other Parameters |
|
| Cooling method |
Air cooling |
| Operating noise |
≤50dB |
| Protection Level |
IP21 |
| Charging ambient temperature |
0°C~45°C |
| Discharge ambient temperature |
-10℃~45℃ |
| Workplace humidity |
25%-85% RH (No condensation) |
| Storage environment humidity |
25%-85% RH (No condensation) |
| Size |
151.4*90.0*80.0mm |
| Accessories |
|
| Complete machine |
1 |
| 120W Adapter |
1( Optional for users ) |
| XT60 Wire |
1 |
| XT90 Wire |
1 |
| Instruction Manual |
1 |
Four , Hazard Warning
1 1. Disassembly or reassembly of internal components is prohibited.
The product is equipped with protective mechanisms and circuits to prevent hazards. Improper disassembly or reassembly can compromise these protective functions, potentially leading to overheating, smoking, or even combustion.
2. Prohibition of allowing Battery cable reverse connection
Do not connect the battery’s positive and negative terminals. Reverse connection , An extremely high current will flow, which will damage the fuse.
3 , Avoid use near heat sources
Do not place near open flames, ovens, or exceed 80°C When used in such an environment, overheating can cause internal short circuits, leading to heating, smoking, deformation, or even combustion.
4 , Do not soak the product to prevent internal electrical components from Road To be made wet
Do not For use in humid environments, Fever and smoking may occur. or Combustion.
5 1. Prohibit disassembling equipment while it is powered on.
When the product is in operation, Because it is connected to a standalone battery. , Be sure to power off the device before disassembling it. And unplug the power cord. , ensure that all output interfaces are de-energized.

Keywords:
Leave a Message
Professional service team response